Kyoritsu

  • Filter

Waterproof handheld Infrared Thermometer • Safe even if getting wet. Dustproof and waterproof structure of IP67. • Possible to wash • Please feel secure to use the product on the spot, made from ABS resin of antibacterial specification. • Shock-proof structure: No damage even if dropped from the height of 1m. • With auto-power-off function, preventing consumption of the battery • Wide Temperature Range of -40ºC to 300ºC • Small and light: Possible to measure easily by one hand. • Portable type: Convenient to carry

Continuity and Insulation Testing • Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live • Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing • Integral overload protection on internal continuity and insulation test circuitry • Autoranging • 500V DC test voltage for insulation tests • 200mA short circuit current on continuity ranges

Continuity:20/200Ω200mA Test Current • Insulation:500/1000V, 20/200MΩ1mA Rated Test Current • Loop Impedance:20/2000Ω15mA Test Current at 2000Ω (No RCD Trip) • RCD:10/30/100/300/500mAx1/2, x1, Fast Trip(40ms), DC, Auto Ramp • Test of a large kind of RCD's:Standard, Selective, AC and A(DC sensitive breakers) • Uc(Contact Voltage): 100V • Designed to IEC 61010-1, IEC 61557 • Data Memory:300 measured results • The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

Complies with IEC 61557 • Designed to IP 54 Rating • Live circuit and wiring connection check LED's • Triple ranges insulation tests at 250, 500 and 1000V • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip) • Phase angle selection on RCD ranges • Polarity switch for continuity tests • Auto-null facility for continuity tests • Earth probe for loop impedance testing on extraneous metalwork • Contact Voltage Reading • Test of a large kind of RCD's: Standard, Selective, AC and A(DC sensitive breakers)

Continuity Measurement Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display. Insulation Measurement Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display. Loop Impedance Measurement A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's. A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW...

Designed to meet IEC 61010-1 CAT.III 600V • Test leads with remote control switch.(For insulation&Simplified Earth Test) • Back light function. • Color coded scales and range switch position for easy reading. • Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance. • Can be hung around the neck for both hand’s operation.

Category: Combi Tester

Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results. • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater. • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range. • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current. • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings. • Test of a large kind of RCD's:Standard, Selective, AC and A (DC sensitive breakers). • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. • RCD Ramp test in order to indicate the actual tripping current of RCD. • Contact Voltage Reading (UC). with two selectable contact voltage limits (50 and 25V). • Visual indication of correct wiring status and automatic lock-out if test resistors overheats. • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54. • The...

The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage. Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.