New electronic smoke tester from Germany - Quality Workmanship
The manual measurement of smoke count, which has been used for decades, is history. The new electronic will replace the time-consuming determination of smoke count used up to now. This new technology not only offers more convenience, but also a degree of precision never before achieved in this price class – high-tech for trade experts.
Whether as a tough tool for flue gas measurements on all kinds of oil burners, or as a starter instrument for new tasks in service and maintenance – the testo 308 is fast, system-compatible, extremely reliable and always ready for use.
Pure compatability
The measurement data can be transferred flexibly to the flue gas analyzers testo 327 and testo 330, as well as directly to a Pocket PC or laptop via IrDA. There they are processed further, together with the flue gas analysis values. And of course the smoke count values can be directly transferred to the printer and printed out.
The special benefits:
- Automatic, digital smoke count measurement to one decimal place according to1. BImschV.
- More security due to a heated measurement spot.
- Display of smoke count based on reference filter.
- Constant sampling over 1 minute.
- Efficient thanks to automatic evaluation and digitally transferred measurement values.
- 2 years’ instrument warranty.
[ Features ]
|
Low Concentrated Smoke Detection
|
It is suitable to a small quantity smoke detection because it is designed for a purpose of supporting the safety function of industrial automation equipment.
|
Ionization sensor : Ionization sensor using the current change when the smoke is combined in the ion created by radial rays can detect very low concentrated smoke.
|
LCD Display with Back-Light
|
Local Alarm
|
It can set the alarm concentration by microprocessor. When the detection concentration is larger than the alarm concentration, over 80㏈ alarm sound is generated. It informs whether the smoke occurs.
|
User Selection Menu
|
It is organized suitably for the purpose of use because various artificial intellectuals are provided by microprocessor. It maximizes the effect of detection function because various functions such as alarm concentration setting, detection range setting, and alarm reset setting are properly used.
|
Two–Channel Detection
|
It can monitor the maximum 2 ionization sensor at the same time and can extend the detection space.
|
|
[ Specification ]
|
|
Classification
|
General Type
|
1 or 2 Channel Monitoring
|
Product Type
|
Wall type
|
Detection Principle
|
Ionizations Smoke Chamber
|
Detection Type
|
Diffusion Type
|
Response Time
|
Less 5 sec.
|
Detection Range
|
0 ~ 500 Pcs/L
|
External Output
|
4 ~ 20㎃
|
Power Source
|
DC 24V
|
Alarm Type
|
High / Low 2 Step Alarm – User setting
|
Alarm Reset
|
Manual or automatic – User selection
|
Signal Wire
|
CVVS & CVVSB 1.25sq x 3 Wire - Shield Type
|
Available Current
|
500㎃. Maximum
|
System Initialization Time
|
Less 50 sec.
|
External Structure
|
Monitoring Unit - Metal, Sensor Unit - Aluminum
|
Temperature/Humidity
|
-20℃~ 50℃ / 0 ~ 95% RH (Non-Condensing)
|
Process
|
Digital Process
|
|