Category: Test Leads

Wire : PVC UL 1803 / 18AWG.     length : 1100±30mm    Out diameter : 3.50mm    Temperature tolerance range : -40ºC~105ºC    Braid copper wires : 64 / 0.12mm● Terminal :    Right angle 4mm brass (nickel plated) banana plug with    caged and insulated sheathing to avoid the brass oxidation.● Rating :    EN 61010-031:2002 + A1:2008    CAT III 1000V 10A / CAT IV 600V 10A

Category: Loop Testers

FEATURES ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles    in the ground or external measuring wires.● Earth measurement uses the real earth current path   and the current generated by the electric network,   without the need for any disconnection.● The Earth Resistance displayed is exactly the earth   resistance that the earth current will need to go   through if an earth fault occurs.   (you do not need to add all the bonding points and    connection paths)● Displays voltage supply at the transformer(Line to   Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll   through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and   earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.    ...

FEATURES ● The TEL1 is the Basic Test Equipment an Electrician cannot do   without. TEL1 is a Dual Function Test Instrument utilized to Verify   Electrical Wiring Connections and the Functioning of Earth Leakage   / Residual Current Detectors devices by forcing the ELCB/RCD to   trip.     SPECIFICATIONS         Nominal Voltage System 110V-220V-230V-240Vac available - User Selectable at purchase. System Voltage Frequency 50-60Hz Wiring Check Accuracy Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect. Earth / Ground Current Simulator Accuracy Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum. Overall Rating Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST. Resistance Rating Current Injection System uses Resistors which are Not Continuously Rated. Case Material ABS Safety Standard EN 61010-1 EN...

● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).

FEATURES Multi-purpose Cable Tester ● 165 CB is an ideal tool which can test the correct pin configuration    for different kinds of cables.● For testing:    -RJ45/RJ11 -USB    -COAX -BNC cable    -Multi-wire cable● Auto-scan and manual-check function● Buzzer sound warning for wire status● 2 LED module indicators on the master unit which can    do both of transmitter and receiver functions for   RJ45/RJ11 cable testing. Users don't need to use the receiving unit.● 165 CB provides a variety for checking cable continuity,  open status, short status and miss-wired.  ● Ground (shielded ) wire test.● LED indication for wire status.● Power source : 9V batteryAmplifier Probe ● The Amplifier Probe is designed to identify and trace  wires or cables within a group without damaging the insulation.   ● The flashlight function for easier cable tracing in the dark.● An LED indication for the signal strength. ● Volume control for increased sensitivity and adjustable   to suit work environment.● Recessed...

Category: Cable Tracers

FEATURES Filter Probe ● Works with any Tone Generator to identify wires.● Volume control for increasing sensitivity and    adjustable to suit work environment.● 2 operation modes: Filter on / Filter off.● The auto-off function (5 minutes) prevents battery    consumption.● Power supply is available in any 9V battery with a   life of approximately 50 hours.● A phone jack is designed for headset or handset.● Flashlight function.Tone Generator● Tone Generator is a great tool for locating and    identifying cable pairs or individual conductors.● 162 CB-G doesn't only provide the function of a    tone generator, but also serves as a continuity and   polarity tester.● A tone selector switch located inside the unit for    selection of the fast tone or the slow tone.● Two bi-colored LEDs for Line1 and Line 2 indication       of the polarities of the telephone lines.● The unit has alligator type terminals, a modular    cable of 4 conductors with a strong connector.● The tone and continuity functions are only...

FEATURES ● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value   easier.● Auto ranging designed.● Range change function.● Continuity check.● Diode measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.     SPECIFICATIONS       DC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(1%rdg+5dgt) 800V AC 4.000V 1mV 40.00V 10mV 400.0V 100mV 750V 1V ․Input impedance : 10MΩ DC...

FEATURES ● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ration (DAR).● BS 16 edition.     SPECIFICATIONS       Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ Continuity     Range 0.01Ω~1999Ω Voltmeter     AC V 0-700V DC V 0-950V PI Function ˇ DAR Function ˇ