Kyoritsu

  • Filter

Phase Indicator with open phase checker • Phase indicator designed to check the presence of open phase and also the phase sequence by rotating disk and lamps. • Can check a wide range of 3-phase power source from 110V to 600V.

Category: Earth Testers

Earth Resistance & Resistivity Tester High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range. • Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements. • Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency. • Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc. • Warning for excessive noise and high Auxiliary Earth Spikes resistance.

Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges 20mA/200mA/200A. • Rotary switch for easy one finger power-on and range selection.

Complies with IEC 61557 • Designed to IP 54 Rating • Live circuit and wiring connection check LED's • Triple ranges insulation tests at 250, 500 and 1000V • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip) • Phase angle selection on RCD ranges • Polarity switch for continuity tests • Auto-null facility for continuity tests • Earth probe for loop impedance testing on extraneous metalwork • Contact Voltage Reading • Test of a large kind of RCD's: Standard, Selective, AC and A(DC sensitive breakers)

Category: Power Meter

Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured. • 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis. • One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory. • Direct communication with PC via USB cable

AC CLAMP ADAPTOR Model 8112BNC is an AC clamp adaptor designed for use with oscilloscopes. Output cord has a BNC connector which enables direct observation of current waveform on oscilloscope. Refer to a diagram shown at left for application. Specifications are same as those for Model 8112.

Category: Test Leads

Applicablemodels   1009     1011     1012     1110     2004     2006     2007A     2017     2027     2040     2046R     2055     2056R     2412     2608A   • Test leads • 1,100mm

Tear drop shaped jaws for ease of use in tight places and crowded cable areas. • Designed to meet internationally proven safety standards such as IEC 61010-1, UL3111 and VDE0411. • Three functions in one unit; AC current, AC voltage and resistance. • Resistance range provides audible continuity test. • Frequency response from 40Hz to 1kHz on AC current and voltage ranges.